Related Experiment Video
Updated: Jul 3, 2026

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Accuracy of the flow convergence method for quantification of aortic regurgitation in patients with central versus
Anne-Catherine Pouleur1, Jean-Benoît le Polain de Waroux, Céline Goffinet
1Division of Cardiology, Cliniques Universitaires St-Luc, Université Catholique de Louvain, Brussels, Belgium.
Abstract:
Proximal isovelocity surface area (PISA) has been proposed as a quantitative method to assess the severity of aortic regurgitation (AR). Yet the accuracy of this method in patients with eccentric AR jets is unknown. The aims of this study were to compare the accuracy of the PISA method for the quantification of AR severity in patients with central versus eccentric AR jets and to verify whether imaging from the left parasternal instead of the apical window improves the accuracy of the PISA method in patients with eccentric jets. Fifty patients with AR (21 with central jets and 29 with eccentric jets) underwent PISA and phase-contrast cardiac magnetic resonance (CMR) measurements of AR volume. In patients with eccentric AR jets, PISA measurements obtained from the left parasternal and apical windows were compared. In patients with central AR jets, CMR- and PISA-derived AR volumes were similar (28 +/- 19 vs 30 +/- 20 ml, p = 0.34), were strongly correlated (r = 0.92, p <0.0001), and differed minimally from each other (by 2 +/- 8 ml). In patients with eccentric AR jets, PISA-derived AR volumes underestimated those measured by CMR (38 +/- 22 vs 51 +/- 27 ml, bias -13 +/- 20 ml) and were correlated only fairly (r = 0.69, p <0.001). Imaging from the left parasternal window eliminated the differences between CMR- and PISA-derived AR volumes (51 +/- 27 vs 53 +/- 26 ml, p = 0.24) and improved the correlation between the 2 measures (r = 0.95). In conclusion, in patients with eccentric AR jets imaged from the apical window, the PISA method significantly underestimated AR severity. This was no longer the case when imaging was performed from the left parasternal instead of the apical window.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management