Related Experiment Video
Updated: Jul 3, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
The "laboratory" effect: comparing radiologists' performance and variability during prospective clinical and
David Gur1, Andriy I Bandos, Cathy S Cohen
1Department of Radiology, University of Pittsburgh School of Medicine, 3362 Fifth Ave, Pittsburgh, Pa 15213-31803, USA. gurd@upmc.edu
Purpose:
To compare radiologists' performance during interpretation of screening mammograms in the clinic with their performance when reading the same mammograms in a retrospective laboratory study.
Materials And Methods:
This study was conducted under an institutional review board-approved, HIPAA-compliant protocol; the need for informed consent was waived. Nine experienced radiologists rated an enriched set of mammograms that they had personally read in the clinic (the "reader-specific" set) mixed with an enriched "common" set of mammograms that none of the participants had previously read in the clinic by using a screening Breast Imaging Reporting and Data System (BI-RADS) rating scale. The original clinical recommendations to recall the women for a diagnostic work-up, for both reader-specific and common sets, were compared with their recommendations during the retrospective experiment. The results are presented in terms of reader-specific and group-averaged sensitivity and specificity levels and the dispersion (spread) of reader-specific performance estimates.
Results:
On average, the radiologists' performance was significantly better in the clinic than in the laboratory (P = .035). Interreader dispersion of the computed performance levels was significantly lower during the clinical interpretations (P < .01).
Conclusion:
Retrospective laboratory experiments may not represent either expected performance levels or interreader variability during clinical interpretations of the same set of mammograms in the clinical environment well.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...