Background:
Cardiac resynchronization therapy (CRT) is useful in managing patients with refractory heart failure. To increase efficacy, pacemaker settings are optimized, with Doppler echocardiography being the preferred method. Recently, acoustic cardiography, an automated method that records, analyzes, and displays simultaneous ECG and heart sound data, has been developed. In this study, the suitability of acoustic cardiography as an alternative to Doppler echocardiography in CRT optimization is evaluated.
Methods:
We studied 43 CRT patients undergoing optimization. Using Doppler echocardiography, we determined the optimal atrioventricular (AV) delay with a transmitral flow assessment. For optimization of the interventricular (VV) delay, we used the left ventricular outflow tract velocity time integral (VTI). For acoustic cardiography, we used the electromechanical activation time (EMAT, the interval from QRS onset to the S1). Reproducibility of echocardiography and acoustic cardiography was determined by programming 10 different delay settings twice in random order.
Results:
All 43 subjects underwent AV optimization, and 14 had CRT devices allowing VV optimization. While the intraobserver variability of EMAT and Doppler echocardiography parameter was similar (9.9% vs 8.5%), the reproducibility of EMAT was the highest (r = 0.91) and VTI was the lowest (r = 0.35). The correlation between the optimal AV delays determined by EMAT versus transmitral flow assessment was 0.86 (P < 0.001). The correlation between the optimal VV delays determined by EMAT versus VTI was 0.58 (P < 0.05), perhaps due to the poor reproducibility of the VTI.
Conclusion:
For CRT optimization, acoustic cardiography provides results similar to echocardiography but with improved reproducibility and ease of use.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:40Impact of Intracardiac Neurons on Cardiac Electrophysiology and Arrhythmogenesis in an Ex Vivo Langendorff System
Published on: May 22, 2018
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...