Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Depth of Interaction Calibration and Capabilities in 2×2 Discrete Crystal Arrays and Digital Silicon Photomultipliers.

IEEE transactions on nuclear science·2020
Same author

A Building Block for Nuclear Medicine Imaging Systems Data Acquisition.

IEEE transactions on nuclear science·2013
Same author

Multiple-hit parameter estimation in monolithic detectors.

IEEE transactions on nuclear science·2012
Same author

Measurements of entrance-surface vs. conventional single-ended readout of a monolithic scintillator.

IEEE transactions on nuclear science·2012
Same author

Multiple-hit parameter estimation in monolithic detectors.

IEEE transactions on medical imaging·2012
Same author

Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes.

IEEE transactions on nuclear science·2012
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: Jul 2, 2026

Additive Manufacturing-Enabled Low-Cost Particle Detector
06:05

Additive Manufacturing-Enabled Low-Cost Particle Detector

Published on: March 24, 2023

Recent developments in PET detector technology.

Tom K Lewellen1

  • 1Division of Nuclear Medicine, University of Washington Medical Center, 222 Old Fisheries Science Center, Seattle, Washington 98195, USA. tkldog@u.washington.edu

Physics in Medicine and Biology
|August 13, 2008
PubMed
Summary
This summary is machine-generated.

Advancements in Positron Emission Tomography (PET) detector technology are crucial for improved metabolic imaging. This review explores recent innovations in PET detectors, focusing on enhancing spatial resolution, timing, and sensitivity for clinical and research applications.

More Related Videos

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out
07:10

Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out

Published on: November 9, 2018

Related Experiment Videos

Last Updated: Jul 2, 2026

Additive Manufacturing-Enabled Low-Cost Particle Detector
06:05

Additive Manufacturing-Enabled Low-Cost Particle Detector

Published on: March 24, 2023

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out
07:10

Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out

Published on: November 9, 2018

Area of Science:

  • Nuclear Medicine
  • Medical Imaging
  • Detector Physics

Background:

  • Positron Emission Tomography (PET) is a vital metabolic imaging tool with a long history.
  • Detector modules are critical components of PET systems, with a rich research and development background.
  • Technology transfer from high-energy physics has historically influenced PET detector design.

Purpose of the Study:

  • To review recent developments in Positron Emission Tomography (PET) detector technology.
  • To highlight innovations aimed at improving spatial resolution, timing, and sensitivity.
  • To discuss the ongoing quest for cost-effective PET detector solutions.

Main Methods:

  • Review of existing literature and research on PET detector modules.
  • Exploration of various detector technologies, including scintillators, wire chambers, and solid-state devices.
  • Analysis of trends driven by clinical PET/CT scanners and pre-clinical research applications.

Main Results:

  • Diverse development of prototype PET detectors, with accelerated progress.
  • Focus on scintillator-based detectors, with continued investigation of alternatives like wire chambers and solid-state devices.
  • Exploration of designs balancing high spatial resolution, fast timing, high sensitivity, and cost-effectiveness.

Conclusions:

  • Continuous innovation in PET detector technology is essential for advancing metabolic imaging.
  • The field is actively pursuing improved performance metrics and cost-effective solutions.
  • Future PET systems will likely benefit from ongoing research into novel detector designs and materials.