Digital modulator and synchronous demodulator system: an alternative to the analog phase detector
G D Renkes1, L R Thorne, W D Gwinn
1Department of Chemistry, University of California, Berkeley, California 94720.
Abstract:
A digital modulator and synchronous demodulator system has been developed which more effectively recovers signals buried in noise than does its analog counterpart. Circuitry of integrated design is described for controlling the modulation in physical measurements and the simultaneous, synchronous demodulation and conversion of the signal into a binary number. This system is especially useful when interfaced with a laboratory computer. The square wave which produces the modulation has purposely lengthened transition times to minimize modulation transients. Demodulation is accomplished by feeding the amplified AM signal into a voltage-controlled oscillator and counting the resulting pulses with counters gated, by the modulation reference circuitry, to count up and down on alternate half-cycles. The number accumulated by the counters is proportional to the true integral of the demodulated signal over a preset number of modulation cycles. The period of the modulation cycle is, in turn, determined by a quartz crystal oscillator. The demodulator can be gated to ignore excessively noisy portions of the modulated signal. Four demodulators with relative gains in ratios of eight operate simultaneously to provide a large dynamic range of more than 10(6). Application of this system to a computer-controlled microwave spectrometer is described. A sample spectrum is given to illustrate the wide dynamic range.
Related Concept Videos
Clipper Circuit
The operation of a clipper circuit can be exemplified by analyzing a dual-clipper configuration setup that integrates two ideal diodes, each paired with a biasing...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Phase-lead and Phase-lag Controllers
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...