Related Experiment Video
Updated: Jul 2, 2026

Murine Oropharyngeal Aspiration Model of Ventilator-associated and Hospital-acquired Bacterial Pneumonia
Published on: June 28, 2018
Role of quantitative endotracheal aspirate and cultures as a surveillance and diagnostic tool for ventilator
Shalini Nair1, Nagamani Sen, John Victor Peter
1Medical Intensive Care Unit, Christian Medical College and Hospital, Vellore, India.
Background:
Accurate diagnosis and appropriate treatment of ventilator associated pneumonia (VAP) is crucial for good outcomes. Endotracheal suctioning is performed in ventilated patients as part of routine care and for tracheal toileting.
Aim:
We evaluated if quantitative endotracheal aspirate (ETA) was a suitable alternative to bronchoalveolar lavage (BAL) for suspected VAP. In addition we assessed if surveillance ETA guided antibiotic selection for subsequent VAP.
Setting And Design:
Prospective study in the surgical intensive care unit (ICU) of a tertiary hospital in India.
Materials And Methods:
Two hundred consecutive patients with mean (standard deviation) APACHE II score of 12.3+/-5 and requiring mechanical ventilation beyond 48 hours underwent surveillance ETA cultures. A second ETA and BAL were performed if the patient developed features of VAP. The threshold for microbiological diagnosis of VAP was taken as 10 5 colony forming units/ml (cfu/ml) for ETA and 10 4 cfu/ml for BAL.
Statistical Analysis:
The sensitivity and specificity of surveillance and concurrent ETA aspirate cultures were compared with BAL cultures.
Results:
VAP was suspected clinically and corroborated radiologically in 27/177 patients (15.3%). Although microbiological support for VAP was obtained by ETA in 19 patients, bronchoscopy was possible only in 13 patients, 8 of whom had isolates at significant threshold. Of the 16 organisms isolated from BAL, 11 were of significant threshold with 9/11 (82%) BAL isolates having a similar antibiogram to a concurrent ETA. Only one BAL isolate (9%), at significant threshold, was not isolated on a concurrent ETA. On the other hand just 6/11 BAL isolates (55%) had an identical antibiogram to surveillance ETA. BAL had 3 additional isolates (27%) at significant threshold not isolated on surveillance ETA.
Conclusions:
Concurrent quantitative ETA could substitute BAL cultures for VAP. Surveillance ETA at 48 hours of ventilation does not appear to assist with antibiotic selection for a subsequent VAP.
Related Concept Videos
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Pneumonia III: Complications and Assessment
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Sputum Studies I: Gram Stain, cytology, and Acid-fast smear and culture
Gram Stain
The Gram Stain is an integral part of sputum studies. It involves the staining of sputum, which permits...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
