Related Experiment Video

Updated: Jul 2, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
04:41

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner

Published on: June 6, 2025

An alternative direction for proximal locking in retrograde femoral nails

Michael Prayson1, Michael Herbenick, Karl Siebuhr

  • 1Department of Orthopedic Surgery, Wright State University, Dayton, Ohio, USA.

Orthopedics
|August 22, 2008
PubMed

Abstract:

Lateral-to-medial proximal interlocking screw insertion for retrograde femoral nails avoids potential neurovascular injury while maintaining stable interlocking mechanics.

More Related Videos

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
07:41

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice

Published on: November 13, 2016

Related Experiment Videos

Last Updated: Jul 2, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
04:41

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner

Published on: June 6, 2025

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
07:41

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice

Published on: November 13, 2016

Related Concept Videos

Self-Locking Screw01:16

Self-Locking Screw

A square-threaded screw jack is a mechanical device widely used for lifting heavy loads or applying considerable force. One of the key features that can make a screw jack more effective and reliable is its self-locking capability.
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.

Articles linked to this work by shared authors, journal, and citation graph.

Simultaneous Bilateral Patellar Tendon Ruptures Treated with Primary Repair and Dermal Allograft Augmentation: A Case Report.

Journal of orthopaedic case reports·2025

Increased stiffness with medial column screw supplementation of lateral locking plate for distal femur fractures: a biomechanical study.

Archives of orthopaedic and trauma surgery·2025

Increased risk of hip fracture mortality associated with intraoperative hypotension in elderly hip fracture patients is related to under resuscitation.

Journal of clinical orthopaedics and trauma·2022

Variability of orthopedic physician fracture location identification: Implications for bone stimulator treatment.

Orthopaedics & traumatology, surgery & research : OTSR·2020

Orthopedic Trauma: Extremity Fractures.

Military medicine·2018

Minimally invasive plate osteosynthesis versus conventional open insertion techniques for osteosynthesis.

Injury·2018

GsMTx4 Alleviates Knee Osteoarthritis by Inhibiting PIEZO1/2-mediated Chondrocyte Apoptosis.

Orthopedics·2026

Impact of Methamphetamine Use on Injury Characteristics and Postoperative Outcomes in Upper Extremity Fractures.

Orthopedics·2026

A Distinct Posterior Cruciate Ligament Avulsion Fracture Involving the Weight-bearing Lateral Tibial Plateau as a Single Fragment: A Case Report.

Orthopedics·2026

Staged Soft Tissue Reconstruction of Traumatic Right Foot Degloving Using Wound Matrix.

Orthopedics·2026

Suture Anchor Fixation Combined With Transosseous Tunnels for a Large Patellar Osteochondral Fracture After Acute Patellar Dislocation.

Orthopedics·2026

Characterization of Infrapatellar Fat Pad-derived Cell Concentrates Obtained During Knee Arthroscopy: Nonenzymatic Versus Enzymatic Processing.

Orthopedics·2026

Machine learning-based detection and area quantification of mechanical and corrosion damage in femoral stem tapers.

Journal of the mechanical behavior of biomedical materials·2026

Effect of right ventricular outflow tract material properties on simulated transcatheter pulmonary placement.

Journal of the mechanical behavior of biomedical materials·2026

Effects of initial cell number, maturation stage, and compressive strain on the viscoelastic response of normal human dermal fibroblast spheroids.

Journal of the mechanical behavior of biomedical materials·2026

A deep neural network-enhanced multi-scale coupled model of patient-specific acoustic wave propagation for mechanotransduction stimulation of healthy and osteoarthritic knee articular cartilage.

Biomechanics and modeling in mechanobiology·2026

Self-Reported Plastic-Related Occupational Scenarios and Perceived Support Priorities Among Operating-Room Nursing Staff: A Multicentre Cross-Sectional Survey.

Journal of nursing management·2026

Biomechanical evaluation of a dual-layer cushion for pilot ejection seats: Full-scale dummy tests and finite element analysis.

Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine·2026
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies
Jove
Visualize
Contact Us