HDL: bridging past and present with a look at the future

Angelo M Scanu1, Celina Edelstein

  • 1Department of Medicine, University of Chicago, MC5041, 5841 S. Maryland Ave., Chicago, IL 60637, USA. ascanu@medicine.bsd.uchicago.edu

Clinical and epidemiological studies have shown that HDLs, a class of plasma lipoproteins, heterogeneous in size and density, have an atheroprotective role attributed, for years, to their capacity to promote the efflux of cholesterol from activated cholesterol-loaded arterial macrophages. Recent studies, however, have recognized that the physical heterogeneity of HDLs is associated with multiple functions that involve both the protein and the lipid components of these particles. ApoA-I, quantitatively the major protein constituent, has an amphipathic structure suited for transport of lipids. It readily interacts with the ATP-binding cassette transporter ABCA1, the SR-B1 scavenger receptor; activates the enzyme lecithin-cholesterol acyl transferase (LCAT), which is critical for HDL maturation. It also has antioxidant and antiinflammatory properties, along with the HDL-associated enzymes paraoxonase, platelet activating factor acetylhydrolase (PAF), and glutathione peroxidase. Regarding the lipid moiety, an atheroprotective role has been recognized for lysosphingolipids, particularly sphingosine-1-phosphate (S1P). All of these atheroprotective functions are lost in the post-translational dependent dysfunctional plasma HDLs of subjects with systemic inflammation, coronary heart disease, diabetes, and chronic renal disease. The emerging notion that particle quality has more predictive power than quantity has stimulated further exploration of the HDL proteome, already revealing unsuspected pro- or antiatherogenic proteins/peptides associated with HDL.

Related Concept Videos

Framing Effects03:26

Framing Effects

Information is everywhere and its presentation—such as how and when items are presented—can impact our perceptions and decisions surrounding the info. This broad concept umbrellas framing effects—influences that occur due to the way information is framed in its appearance, whether it’s purely the order or the specific wording of a message. Let’s take a look at numerous ways in which two versions of something can objectively say the same thing, yet we respond in different ways based on the...
Wheatstone Bridge01:29

Wheatstone Bridge

An ohmmeter is a resistance-measuring device. It works by applying a voltage to a resistor of unknown resistance and measuring the current across the resistor. The resistance value is deduced using Ohm's law. Usually, the standard configuration of an ohmmeter comprises a voltmeter or an ammeter. However, such configurations are limited in accuracy because the meters alter the voltage applied to the resistor and the current that flows through it.
Thus, for accurate resistance measurements, a...
Design Example: Strain Gauge Bridge or Wheatstone Bridge01:15

Design Example: Strain Gauge Bridge or Wheatstone Bridge

The utilization of strain gauges as transducers for converting mechanical strain into electrical signals is a common practice in various engineering applications. These strain gauges are frequently integrated into Wheatstone bridge circuits to accurately measure parameters such as force or pressure. Within this context, each element within the circuit exhibits a resistance that undergoes subtle variations when subjected to mechanical strain. The primary objective is to convert minuscule...
Bridge rectifier01:24

Bridge rectifier

The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Next-generation Sequencing03:00

Next-generation Sequencing

The first human genome sequencing project cost $2.7 billion and was declared complete in 2003, after 15 years of international cooperation and collaboration between several research teams and funding agencies. Today, with the advent of next-generation sequencing technologies, the cost and time of sequencing a human genome have dropped over 100 fold.
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features.
Spanning Openings in Brick Walls01:20

Spanning Openings in Brick Walls

In brick wall construction, supporting structures are crucial for openings like windows and doors to maintain the integrity and support the weight of the wall above. These supports include lintels, corbels, and arches, each serving specific structural purposes.
Lintels are primary supports used to span openings and can be crafted from materials such as reinforced concrete, steel-reinforced brick masonry, or simple steel angles. These are straightforward to install and are typically concealed...