Related Experiment Video
Updated: Jul 2, 2026

Using a Thermal Camera to Measure Heat Loss Through Bird Feather Coats
Published on: June 17, 2020
The effect of temperature on bougies: a photographic and manikin study
1Royal National Throat Nose and Ear Hospital, London, UK. oliviamingo@hotmail.co.uk
Abstract:
We investigated the effect of temperature on single use and reuseable bougies. In a photographic study, three bougies (Portex Venn reuseable (R), Portex single use (S) and Breathesafe single use (B)) were exposed to increasing temperatures and sequential photographs were taken of the bougies uncoiling from a preformed curve. Bougie type was associated with rate of uncoiling, type R maintaining its curve the longest but changing temperature did not affect this. In a randomised cross-over manikin study, 16 anaesthetists attempted to pass two bougies (Portex reuseable (R) and Portex single use (S)) at three temperatures (10, 20 and 30 degrees C) into the trachea of a manikin. Type R was significantly associated with higher success rate of tracheal placement compared to type S. Change of temperature was significant with success rate increasing with lower temperature. The odds of success at 10 degrees C was six times that at 30 degrees C (OR (95%) 6.7 (1.7, 25.7)). We concluded that both bougies performed best at 10 degrees C.
More Related Videos
06:21Fabrication of Microscope Stage for Vertical Observation with Temperature Control Function
Published on: July 31, 2019
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Related Concept Videos
Effect of Temperature Change on Reaction Rate
Effects of Temperature on Free Energy
Factors Affecting Body Temperature
Factors may include:
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Le Chatelier's Principle: Changing Temperature
To understand this phenomenon, consider the elementary reaction: