Related Experiment Video
Updated: Jul 2, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
[Determination of monoethylglycinexylidide concentration in serum using solid phase extraction and capillary gas
Zhenxia Wang1, Ruiming Zhang, Wei Cao
1General Surgery Department, First Affiliated Hospital of Inner Mongolia Medical College, Hohhot 010050, China. wzhenxia@163.com
Abstract:
A novel method for the determination of monoethylglycinexylidide (MEGX) (lidocaine metabolin) in serum using solid phase extraction (SPE) and capillary gas chromatography-mass spectrometry (GC-MS) was established. The serum sample was extracted with a CN-SPE column. An HP-5MS capillary column (15 m x 0.25 mm x 0.1 microm) was used. The initial temperature of the column was set at 100 degrees C, held for 1 min, then raised to 200 degrees C at 40 degrees C/min, and held at 200 degrees C for 0.5 min. The sample size was 2 microL, and the split ratio was set at 1 : 1. The carrier gas was high purity helium with a flow rate of 1.0 mL/min. The monitoring ions for the determination were m/z 58 for MEGX and m/z 86 for procaine (internal standard). The calibration curve of MEGX had good linear relationship in the range of 1.562 - 25 ng/mL ( r = 0.998 1). The limit of detection was 0.5 ng/mL. The extraction recovery ranged from 80.1% to 85.7%. The method advanced the quantitative analysis of MEGX in serum by combining rapid and efficient SPE with specific and sensitive quantitation by GC-MS.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...