Related Experiment Video
Updated: Jul 2, 2026

Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
Computerized navigation for treatment of slipped femoral capital epiphysis
Yoram Weil1, Andrew Pearle, Meir Liebergall
1Orthopedic Trauma Service, Hospital for Special Surgery, 535 East 70th St., New York, NY 10021, USA. yoramweil@gmail.com
Abstract:
In situ pinning with a single screw is the treatment of choice for symptomatic slipped capital femoral epiphysis (SCFE). Some technical features are critical and include proper screw entry point, screw direction in relation to the epiphysis, and the length of screw. These are complicated by the deformity created as a result of the posterior slip of the epiphysis. Fluoroscopic based computerized navigation system can increase precision in screw placement while performing the surgical task, and markedly reduce radiation. By using real fluoroscopy-based navigation, the screw can be placed with only two fluoroscopic images. Entry point, length, and precise direction can all be easily determined through this technique.