Related Experiment Video
Updated: Jul 2, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Cardiovascular dynamics in healthy subjects with differing heart rate responses to tilt
Farah A Ramirez-Marrero1, Nisha Charkoudian, Emma C Hart
1Department of Anesthesiology, Mayo Clinic College of Medicine, Rochester, MN 55905, USA. ramirez-marrero.farah@mayo.edu
Abstract:
Orthostatic stress such as head-up tilt (HUT) elicits a wide range of heart rate (HR) and arterial pressure (AP) responses among healthy individuals. In this study, we evaluated cardiovascular dynamics in healthy subjects with different HR responses to HUT, but without autonomic dysfunction. We measured AP (brachial artery) and HR (ECG) during 5 min of 60 degrees HUT in 76 healthy normotensive individuals. We then chose individuals on the basis of the extremes of HR responses to HUT (high = DeltaHR > or = 20 beats/min, and low = DeltaHR < or = 10 beats/min; n = 15 per group). Peak HR during HUT was 87 +/- 10 beats/min in the high and 69 +/- 14 beats/min in the low group (P < 0.05). High HR responders had lower systolic pressure at baseline (121 +/- 9 vs. 129 +/- 11 mmHg, P < 0.05) and during HUT (120 +/- 10 vs. 131 +/- 13 mmHg, P < 0.05), and higher plasma norepinephrine (NE) response to HUT (DeltaNE: 156.9 +/- 17.8 vs. 89.0 +/- 17.2 pg/ml; P < 0.05). DeltaNE during HUT was also significantly correlated with DeltaHR when all 76 subjects were included in a regression analysis (r = 0.39; P < 0.001). Pulse pressure was lower during HUT in high HR responders compared with low HR responders (45 +/- 1 vs. 55 +/- 2 mmHg, P < 0.05). High HR responders also had larger fluctuations in systolic and pulse pressure during HUT (coefficient of variation = 10.7 +/- 0.7 vs. 5.7 +/- 0.3%; 7.9 +/- 0.5 vs. 4.1 +/- 0.4%, respectively, P < 0.05). Sex distribution was different between groups (high: 5 women, 10 men; low: 10 women, 5 men). Higher HR with lower AP during HUT is consistent with normal baroreflex mechanisms of integration. Although interindividual variability appears to be a fundamental part of cardiovascular regulation, the mechanisms of these differences and the sex discrepancy requires further investigation.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...