Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Velocity and Position by Integral Method01:13

Velocity and Position by Integral Method

If acceleration as a function of time is known, then velocity and position functions can be derived using integral calculus. For constant acceleration, the integral equations refer to the first and second kinematic equations for velocity and position functions, respectively.
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Neural phase microscopy with metasurface optics for real-time and nanoscale quantitative phase imaging.

Nature communications·2026
Same author

Multi-objective optimization of dynamic VO<sub>2</sub> metagrating: broadband polarization-independent transmission modulator.

Optics express·2024
Same author

Metasurface folded lens system for ultrathin cameras.

Science advances·2024
Same author

Speckle reduced holographic display system with a jointly optimized rotating phase mask.

Optics letters·2024
Same author

Multiwavelength Achromatic Deflector in the Visible Using a Single-Layer Freeform Metasurface.

Nano letters·2024
Same author

Freeform metasurface color router for deep submicron pixel image sensors.

Science advances·2024

Related Experiment Video

Updated: Jul 2, 2026

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects

Published on: February 8, 2014

Undistorted pickup method of both virtual and real objects for integral imaging.

Joonku Hahn1, Youngmin Kim, Eun-Hee Kim

  • 1School of Electrical Engineering, Seoul National University, Gwanak-Gu Sillim-Dong, Seoul 151-744, Korea.

Optics Express
|September 6, 2008
PubMed
Summary

A new optical pickup method for integral imaging corrects distortions for both real and virtual objects. This system aligns view volumes, eliminating the need for computational compensation during image capture.

More Related Videos

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
10:28

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

Published on: July 5, 2016

Measuring the Complete-arch Distortion of an Optical Dental Impression
06:51

Measuring the Complete-arch Distortion of an Optical Dental Impression

Published on: May 30, 2019

Related Experiment Videos

Last Updated: Jul 2, 2026

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects

Published on: February 8, 2014

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
10:28

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

Published on: July 5, 2016

Measuring the Complete-arch Distortion of an Optical Dental Impression
06:51

Measuring the Complete-arch Distortion of an Optical Dental Impression

Published on: May 30, 2019

Area of Science:

  • Optics
  • Image Processing
  • 3D Imaging

Background:

  • Integral imaging captures 3D scenes using a lens array, but distortions can arise from misaligned view volumes between pickup and display.
  • Existing methods often require computationally intensive post-processing to correct these distortions.

Purpose of the Study:

  • To propose and validate an optically corrected pickup method for integral imaging.
  • To eliminate distortions caused by view volume misalignment in integral imaging systems.
  • To enable distortion-free pickup of both real and virtual objects without computational compensation.

Main Methods:

  • Implemented a pickup system with imbricate view volumes equivalent to integral imaging display.
  • Utilized 4f optics to transform view volumes.
  • Employed a lens array and telecentric lens to define directions of view.

Main Results:

  • The proposed system demonstrated optically corrected pickup for both real and virtual objects.
  • Experimental results confirmed the absence of distortion due to view volume alignment.
  • The method avoids the need for computational compensation.

Conclusions:

  • The developed optical method effectively corrects distortions in integral imaging pickup.
  • This approach simplifies the integral imaging process by removing computational requirements.
  • The system is suitable for capturing both real and virtual 3D objects accurately.