Related Experiment Video
Updated: Jul 1, 2026

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
Published on: October 15, 2018
Metal-ligand solution equilibria studied by electrospray ionization mass spectrometry: effect of instrumental
Valerio B Di Marco1, G Giorgio Bombi, Stefano Zambon
1Dipartimento di Scienze Chimiche, Università degli Studi di Padova, Padova, Italy. valerio.dimarco@unipd.it
Abstract:
Electrospray ionization mass spectrometry (ESI-MS) is being increasingly employed in the study of metal-ligand equilibria in aqueous solution. In the present work, the ESI-MS spectral changes due to different settings of the following instrumental parameters are analyzed: the solution flow rate (F(S)), the nebulizer gas flow rate (F(G)), the sprayer potential (E), and the temperature of the entrance capillary (T). Twenty-eight spectra were obtained for each of six samples containing aluminum(III) and 2,3-dihydroxypyridine at various pH, in the absence or in the presence of a buffer and of sodium ions. Among the considered instrumental parameters, T produced the largest effects on the ionic intensities. F(S) and F(G) affected the ESI-MS spectra to a lower extent than T. In the investigated conditions E had the weakest effects on the spectra.The correlations observed between the ionic intensities and these instrumental parameters were interpreted considering the presence of three kinds of perturbations occurring in the ESI-MS ion source: formation of some dimers in the droplets, different transfer efficiencies from the droplets to the gas phase for different complexes (according to their surface activity), and subsequent partial thermal decomposition of the dimers and of one of the monomeric complexes in the gas phase. Our results show that the evaluation of the effects produced in the ESI-MS spectra by a change of instrumental parameters can allow to identify the perturbations occurring when metal-ligand solutions are studied by ESI-MS.
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
12:59A Study of the Complexation of Mercury(II) with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrum: Interpretation
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrometers