Determination of short-chain branching content in polyethylene by pyrolysis comprehensive multidimensional gas

Patric Eckerle1, Matthias Pursch, Hernan J Cortes

  • 1Dow Deutschland GmbH, Analytical Sciences, Rheinmuenster, Germany.

Related Concept Videos

Radical Chain-Growth Polymerization: Chain Branching01:17

Radical Chain-Growth Polymerization: Chain Branching

The skeletal structure of polymers synthesized via radical polymerization is always branched. For example, the polymerization of ethylene by radical polymerization results in a low-density grade of polyethylene with a heavily branched skeletal structure. Here, the radical site abstracts hydrogen from the growing chain, and the radical site shifts from the end (a primary carbon center) to anywhere within the growing chain (a secondary carbon center). Consequently, the part of the chain from the...
Mass Spectrometry: Branched Alkane Fragmentation01:29

Mass Spectrometry: Branched Alkane Fragmentation

This lesson delves into the mass spectrometry of branched alkane fragmentation. Branched alkanes possess secondary or tertiary carbon atoms, which generate relatively stable carbocations if the cleavage occurs at the branching point. The high stability of carbocations drives the instant fragmentation of branched alkanes. Accordingly, the branched alkane's molecular ion peak is very weak or invisible in the mass spectra, especially in comparison to a linear alkane.
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Cycloalkane Fragmentation01:05

Mass Spectrometry: Cycloalkane Fragmentation

In mass spectrometry, cycloalkanes exhibit distinct fragmentation patterns due to the inherent stability of their molecular ions compared to linear or branched alkanes. The ring structure of cycloalkanes provides additional stability to the molecular ions, often resulting in prominent ion peaks in the mass spectrum.
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Mass Spectrometry: Long-Chain Alkane Fragmentation01:18

Mass Spectrometry: Long-Chain Alkane Fragmentation

The molecular ions of linear alkanes prefer to fragment at the carbon-carbon bond away from the end of the chain since the cleavage of an inner bond creates a stable carbocation and a stable radical. Consequently, the mass signals of linear alkanes feature intense peaks in the middle of the mass-to-charge ratio plot with weaker peaks on either end. The fragmentation of each carbon-carbon bond with the release of a methyl group in each splitting leads to prominent peaks in the mass spectra...