Raman spectroscopy as a process analytical technology (PAT) tool for the in-line monitoring and understanding of a
T R M De Beer1, C Bodson, B Dejaegher
1Laboratory of Pharmaceutical Chemistry and Drug Analysis, Department of Pharmaceutical Analysis, Ghent University, Harelbekestraat 72, B-9000 Ghent, Belgium. Thomas.DeBeer@UGent.be
Abstract:
The aim of this study is to propose a strategy to implement a PAT system in the blending step of pharmaceutical production processes. It was examined whether Raman spectroscopy can be used as PAT tool for the in-line and real-time endpoint monitoring and understanding of a powder blending process. A screening design was used to identify and understand the significant effects of two process variables (blending speed and loading of the blender) and of a formulation variable (concentration of active pharmaceutical ingredient (API): diltiazem hydrochloride) upon the required blending time (response variable). Interactions between the variables were investigated as well. A Soft Independent Modelling of Class Analogy (SIMCA) model was developed to determine the homogeneity of the blends in-line and real-time using Raman spectroscopy in combination with a fiber optical immersion probe. One blending experiment was monitored using Raman and NIR spectroscopy simultaneously. This was done to verify whether two independent monitoring tools can confirm each other's endpoint conclusions. The analysis of the experimental design results showed that the measured endpoints were excessively rounded due to the large measurement intervals relative to the first blending times. This resulted in effects and critical effects which cannot be interpreted properly. To be able to study the effects properly, the ratio between the blending times and the measurement intervals should be sufficiently high. In this study, it anyway was demonstrated that Raman spectroscopy is a suitable PAT tool for the endpoint control of a powder blending process. Raman spectroscopy not only allowed in-line and real-time monitoring of the blend homogeneity, but also helped to understand the process better in combination with experimental design. Furthermore, the correctness of the Raman endpoint conclusions was demonstrated for one process by using a second independent endpoint monitoring tool (NIR spectroscopy). Hence, the use of two independent techniques for the control of one response variable not only means a mutual confirmation of both methods, but also provides a higher certainty in the determined endpoint.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Tandem Mass Spectrometry