Related Experiment Video
Updated: Jun 29, 2026

How to Build a Laser Speckle Contrast Imaging (LSCI) System to Monitor Blood Flow
Published on: November 11, 2010
A model of speckle contrast in optical coherence tomography for characterizing the scattering coefficient of
1Key Laboratory of Optoelectronic Science and Technology for Medicine, Ministry of Education, Fujian Normal University, Fuzhou, Fujian, People's Republic of China.
Abstract:
We present a theoretical model for analyzing the speckle contrast of optical coherence tomography (OCT). This model is based on the addition of noise and an OCT signal in the logarithmic scale. The theoretical model reveals that, for the superficial layer of homogenous tissue, the contrast ratio is a linear function of the location of the coherence gate in the sample and the slope of this linear dependence is proportional to the scattering coefficient. The theoretical model is consistent with the experimental results, suggesting that the slope can be useful to characterize the scattering coefficient of the homogenous samples.
More Related Videos
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...