Simultaneous sampling and analysis for vapor mercury in ambient air using needle trap coupled with gas
Jibao Cai1, Gangfeng Ouyang, Ying Gong
1Department of Chemistry, University of Science and Technology of China, Hefei 230026, China. jbcai@ustc.edu.cn
Abstract:
A needle trap (NT) technique for simultaneous sampling and analysis of vapor and particle mercury in ambient air using gold wire filled in a syringe needle has been developed. This NT technique relies on gold amalgamation rather than adsorption/absorption to traditional solid-phase microextraction. Hg trapped by Au-amalgamation NT is thermally desorbed in a hot injection port of a gas chromatograph; desorbed Hg is then determined by the coupled mass spectrometer. This simultaneous sampling and analysis technique were optimized, tested, and used for the collection and accurate determination of elemental Hg in ambient air. Linear calibration curves were obtained for Hg sampling by NT when mass spectrometry (MS) was used for detection; they spanned over 4 orders of magnitude. MS offered excellent sensitivity and selectivity. Selected ion monitor (SIM) mode was used for the linear calibration curves. The selected quantitation ion was m/z 202, since m/z 202 was the strongest isotope of mercury mass spectrum. The method was verified with HgCl(2) spiked solution samples. An excellent agreement was found between the results obtained for the Hg-saturated air samples and HgCl(2) spiked solution samples. The use of the Au-amalgamation gas-sampling needle trap method, for the measurement of Hg in air and Hg(2+) water samples, is described herein.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...