Abstract:
The mean vibration transmissibility values were measured for cotton work gloves commonly used in vibration-generating workplaces to evaluate the vibration isolating performance of cotton work gloves. The mean vibration transmissibility values of work cotton gloves were compared with those of four types of anti-vibration gloves measured in the same way. All the measurements were performed based on the newly issued JIS T8114 that is identical to ISO10819. Also, linear transmissibility values were calculated from the measured data. Cotton work glove samples did not satisfy the requirements specified in JIS T8114. All the test samples showed mean vibration transmissibility values of more than 1.0 for spectra M and H. In contrast, all the anti-vibration gloves tested in this study satisfied the JIS T8114 requirements. The linear transmissibility values of cotton work gloves were consistently higher than those of anti-vibration gloves for spectrum H. The linear transmissibility values of cotton work gloves were steady at about 0.9 up to 200 Hz, then increased with vibration frequency to about 1.0 at 400 Hz. In contrast, the linear transmissibility values of anti-vibration gloves increased with frequency to 1.0 at 30 Hz and then decreased with small peaks at 100 Hz and 300 Hz. Our results suggest that cotton work gloves do not show enough vibration-isolating performance. Therefore, attention should be paid to encouraging the widespread use of anti-vibration gloves in place of cotton work gloves to reduce exposure to hand-arm vibration.
Related Concept Videos
Personal Protective Equipment
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Hand hygiene
Hand washing...
Characteristics of Dry Friction
Before the wheelbarrow starts moving, the static frictional force acts tangentially to the contact surface, opposing the force that is about to induce the motion. This frictional force prevents the...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
PPE Use in Healthcare Settings II: Doffing