Related Experiment Video
Updated: Sep 18, 2025

Development of an Uncomplicated Mild Traumatic Brain Injury Model Modified by Weight-Drop Method and Evidenced by Magnetic Resonance Imaging
Published on: April 11, 2025
A micromechanical procedure for modelling the anisotropic mechanical properties of brain white matter
N Abolfathi1, A Naik, M Sotudeh Chafi
1Department of Mechanical Engineering and Applied Mechanics, North Dakota State University, Fargo, ND, USA.
Abstract:
This paper proposes a micromechanics algorithm utilising the finite element method (FEM) for the analysis of heterogeneous matter. The characterisation procedure takes the material properties of the constituents, axons and extracellular matrix (ECM) as input data. The material properties of both the axons and the matrix are assumed to have linear viscoelastic behaviour with a perfect bonding between them. The results of the modelling have been validated with experimental data with material white input from brainstem by considering the morphology of brainstem in which most axons are oriented in longitudinal direction in the form of a uniaxial fibrous composite material. The method is then employed to examine the undulations of axons within different subregions of white matter and to study the impact due to axon/matrix volume fractions. For such purposes, different unit cells composed of wavy geometries and with various volume factions have been exposed to the six possible loading scenarios. The results will clearly demonstrate the undulation and axon volume fraction impacts. In this respect, undulation affects the material stiffness heavily in the axon longitudinal direction, whereas the axons' volume fraction has a much greater impact on the mechanical properties of the white matter in general. Also the results show that the created stresses and strains in the axons and matrix under loading will be impacted by undulation change. With increase in undulation the matrix suffers higher stresses when subjected to tension, whereas axons suffer higher stresses in shear. The axons always exhibit higher stresses whereas the matrix exhibits higher strains. The evaluated time-dependent local stress and strain concentrations within a repeating unit cell of the material model are indicative of the mechanical behaviour of the white tissue under different loading scenarios.
More Related Videos
11:19Characterizing Multiscale Mechanical Properties of Brain Tissue Using Atomic Force Microscopy, Impact Indentation, and Rheometry
Published on: September 6, 2016
15:263D Modeling of the Lateral Ventricles and Histological Characterization of Periventricular Tissue in Humans and Mouse