Related Experiment Video
Updated: Jun 29, 2026

Green Synthesis of Quinoline-Based Ionic Liquid
Published on: September 27, 2024
Ionic liquids as mobile phase additives for the high-performance liquid chromatographic analysis of fluoroquinolone
Antonio V Herrera-Herrera1, Javier Hernández-Borges, Miguel Angel Rodríguez-Delgado
1Departmento de Química Analítica, Nutrición y Bromatología, Universidad de La Laguna, Avda. Astrofísico Fco. Sánchez s/n, 38071 La Laguna, Tenerife, Islas Canarias, Spain.
Abstract:
In this work, four ionic liquids differing in the length of the alkyl chain on the imidazolium cation and one ionic liquid containing tetraethylammonium, all with the same counterion, (i.e. 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIm-BF(4)), 1-butyl-3-methylimidazolium tetrafluoroborate (BMIm-BF(4)), 1-hexyl-3-methylimidazolium tetrafluoroborate (HMIm-BF(4)), 1-methyl-3-octylimidazolium tetrafluoroborate (MOIm-BF(4)), and tetraethylammonium tetrafluroborate (Et(4)N-BF(4))) were tested as mobile phase additives for HPLC separation of a group of seven basic fluoroquinolone (FQ) antibiotics for human and veterinary use (i.e. fleroxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, sarafloxacin, and difloxacin) using a conventional reversed-phase Nova-Pak C(18) column. Fluorescence detection was used. Among the ionic liquids selected, use of BMIm-BF(4) enabled effective separation of these compounds with relatively low analysis time (14 min). The best separation was achieved by isocratic elution at 1 mL min(-1) with 5 mmol L(-1) BMIm-BF(4) and 10 mmol L(-1) ammonium acetate at pH 3.0 with 13% (v/v) acetonitrile. Limits of detection (LODs) for fluorescence detection were in the range 0.5-11 microg L(-1). The method was tested by analyzing several water samples after the optimization of a suitable solid-phase extraction (SPE) procedure using Oasis HLB cartridges. Mean recovery values were above 84% for all analytes with LODs in the range 1-29 ng L(-1).
More Related Videos
06:44From Molecules to Materials: Engineering New Ionic Liquid Crystals Through Halogen Bonding
Published on: March 24, 2018
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Instrumentation
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...