Updated: Jun 28, 2026

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
05:58

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes

Published on: March 22, 2022

First basic performance evaluation of the XE-2100 haematology analyser.

I Tsuda1, M Hino, T Takubo

  • 1Department of Clinical and Laboratory Medicine, Osaka City University Medical School, Japan.

Journal of Automated Methods & Management in Chemistry
|October 18, 2008
PubMed
Summary

The new XE-2100 haematology analyser offers reliable complete blood counts and leukocyte differentials. Its performance evaluation showed excellent accuracy and reproducibility for clinical laboratory use.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Supercontinuum generation at 1.55 m in a dispersion-flattened polarization-maintaining photonic crystal fiber.

Optics express·2009
Same author

Optical properties of a low-loss polarization-maintaining photonic crystal fiber.

Optics express·2009
Same author

[Tricuspid annuloplasty, pulmonary valve replacement, ventricular septal defect (VSD) patch closure, and right-sided maze procedure 23-years after corrective repair of tetralogy of Fallot].

Kyobu geka. The Japanese journal of thoracic surgery·2009
Same author

Mycoplasmal pneumonia proceeding acute focal bacterial nephritis.

Clinical nephrology·2008
Same author

Ovarian cyclicity and reproductive performance of holstein cows carrying the mutation of complex vertebral malformation in Japan.

Reproduction in domestic animals = Zuchthygiene·2008
Same author

Random evolution and coherence degradation of a high-order optical soliton train in the presence of noise.

Optics letters·2007

Area of Science:

  • Clinical laboratory diagnostics
  • Haematology automation

Background:

  • The XE-2100 is a novel haematology analyser.
  • It offers complete blood counts, leukocyte differentials, reticulocyte analysis, and nucleated red blood cell (NRBC) quantification.

Purpose of the Study:

  • To evaluate the basic performance of the XE-2100 haematology analyser.
  • Assessment included reproducibility, carryover, storage stability, and accuracy.

Main Methods:

  • Evaluation used routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2K.
  • Performance metrics assessed included reproducibility, carryover, storage stability (4°C and room temperature), and accuracy.
  • Comparisons were made against the SE-9000 haematology analyser and manual methods.

More Related Videos

A Point-of-Care Method with Integrated Decision Support Tool to Estimate Anemia at Population Level
05:35

A Point-of-Care Method with Integrated Decision Support Tool to Estimate Anemia at Population Level

Published on: January 19, 2024

Related Experiment Videos

Last Updated: Jun 28, 2026

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
05:58

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes

Published on: March 22, 2022

A Point-of-Care Method with Integrated Decision Support Tool to Estimate Anemia at Population Level
05:35

A Point-of-Care Method with Integrated Decision Support Tool to Estimate Anemia at Population Level

Published on: January 19, 2024

Main Results:

  • Good reproducibility and minimal carryover were observed.
  • Accurate measurements were maintained for up to 48 hours of storage.
  • High correlation (r > 0.9) was found for complete blood counts and leukocyte differentials (neutrophils, lymphocytes, eosinophils) compared to the SE-9000 and manual counts.
  • Nucleated red blood cell (NRBC) and reticulocyte counts demonstrated satisfactory precision and accuracy.
  • Differential counts for bone marrow aspirates correlated well with manual differentials.

Conclusions:

  • The XE-2100 haematology analyser exhibits excellent performance characteristics.
  • The instrument is capable of providing reliable and accurate data for clinical laboratories.