The usefulness of bioelectrical impedance analysis in differentiating dyspnea due to decompensated heart failure
Gaspare Parrinello1, Salvatore Paterna, Pietro Di Pasquale
1Department of Internal Medicine, University of Palermo, Palermo, Italy.
Background:
Acute dyspnea poses a diagnostic challenge for physicians, and the current methods in differentiating cardiac from non-cardiac causes have been limited to date. Recently, the brain natriuretic peptide (BNP) rapid test has been validated in the emergency room. Nevertheless, the early accumulation of fluid in the interstitial space in the body and in the lungs, which characterizes patients with ADHF, is well estimated by BIA. We investigate whether bioelectrical impedance analysis (BIA) can serve as a noninvasive diagnostic tool in the differential diagnosis of acute decompensated heart failure (ADHF) in the emergency department (ED).
Methods And Results:
A total of 292 patients presenting with acute dyspnea to the ED were evaluated by using a conventional diagnostic strategy and rapid BNP measures. Segmental (Seg) and whole-body (WB) BIA resistance (Rz) and reactance (Xc) on entry were immediately detected. After hospital discharge, an expert team classified enrolled patients into ADHF and non-ADHF. A total of 58.9% of patients had ADHF, whereas 41.1% were non-ADHF. ADHF patients showed significantly (P < .001) higher BNP values (591.8 +/- 501 versus 69.5 +/- 42 pg/mL), a significant (P < .001) reduction of Seg (35.5 + 8.2 versus 66.4 + 10.5) and WB (402.3 + 55.5 versus 513.2 + 41.8) Rz (Ohm), and a significant correlation (P < .0001) between BNP and Seg (r = -0,62) and WB (r = -0.63) bioelectrical Rz was also identified. Multiple regression analysis revealed that whole body and segmental BIA were strong predictors of ADHF alone or in combination with BNP.
Conclusions:
Our data suggest that Seg and WB BIA are a useful, simple, rapid, and noninvasive diagnostic adjunct in the early diagnosis of dyspnea from ADHF.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Bode Plots Construction
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Heart Failure IV: Classification and Diagnostic Evaluation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...