Related Concept Videos

Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Overview01:27

Atomic Absorption Spectroscopy: Overview

Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Critical evaluation of the TDx Turbo Nephelometry System.

Clinical chemistry·1988
Same author

Enzymatic assay for creatinine with fixed-time kinetics on a centrifugal analyzer.

Annals of clinical and laboratory science·1984
Same author

Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry.

Clinical chemistry·1983
Same author

Medical education in laboratory testing: an approach incorporating the student's own laboratory results.

American journal of clinical pathology·1983
Same author

Effects of hydrogen peroxide on chemical determinations in urine.

Clinical chemistry·1982
Same author

Fluorescein effect on magnesium and total protein determinations.

Clinical chemistry·1982
Same journal

Automated colorimetric determination of recombinant fungal laccase activity in fermentation sarples using syringaldazine as chromogenic substrate.

The Journal of automatic chemistry·2008
Same journal

Diagnosis of infections in newborns using a new particle-mediated immunoassay for serum C-reactive protein.

The Journal of automatic chemistry·2008
Same journal

Automation photometer of Hitachi U-2000 spectrophotometer with RS-232C-based computer.

The Journal of automatic chemistry·2008
Same journal

An automated system for the measurement of hydrogen peroxide in industrial applications.

The Journal of automatic chemistry·2008
Same journal

Simultaneous spectrophotometric determination of manganese, zinc and cobalt by kernel partial least-squares method.

The Journal of automatic chemistry·2008
Same journal

The automatic methods group newsletter.

The Journal of automatic chemistry·2008
See all related articles

Related Experiment Video

Updated: Jun 28, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

An automated module for atomicabsorption analysis of reduced volatile elements

B W Renoe1

  • 1Departments of Pathology and of Chemistry University of Virginia Charlottesville Virginia 22908 USA.

The Journal of Automatic Chemistry
|January 1, 1982
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Atomic Absorbance Spectroscopy to Measure Intracellular Zinc Pools in Mammalian Cells
13:04

Atomic Absorbance Spectroscopy to Measure Intracellular Zinc Pools in Mammalian Cells

Published on: May 16, 2019

Reducing Willow Wood Fuel Emission by Low Temperature Microwave Assisted Hydrothermal Carbonization
09:46

Reducing Willow Wood Fuel Emission by Low Temperature Microwave Assisted Hydrothermal Carbonization

Published on: May 19, 2019

Related Experiment Videos

Last Updated: Jun 28, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

Atomic Absorbance Spectroscopy to Measure Intracellular Zinc Pools in Mammalian Cells
13:04

Atomic Absorbance Spectroscopy to Measure Intracellular Zinc Pools in Mammalian Cells

Published on: May 16, 2019

Reducing Willow Wood Fuel Emission by Low Temperature Microwave Assisted Hydrothermal Carbonization
09:46

Reducing Willow Wood Fuel Emission by Low Temperature Microwave Assisted Hydrothermal Carbonization

Published on: May 19, 2019