[The value of Doppler cardiotocogram computer analysis system 70 minutes before delivery]
S Schiermeier1, H Hatzmann, J Reinhard
1Frauenklinik der Universität Witten/Herdecke, Marien-Hospital, Witten. Dr.Schiermeier@gmx.de
Background:
Since the second half of the 20th century, foetal wellbeing has been assessed using cardiotocography (CTG) during labour. Many studies have shown that the CTG has very high intra- and interobserver variability. Many score systems have been developed for more objective analysis of the foetal heart rate. The German Society of Obstetrics and Gynaecology recommends the use of computerised analysis programmes for CTG evaluation in order to reduce subjectivity. This study examines whether there is a correlation of foetal outcome with computerised CTG analysis using the "CTG-Online" programme.
Materials And Methods:
Out of 1,251 consecutive deliveries, two groups were selected depending on foetal outcome (very good foetal outcome [n=76] and poor foetal outcome [n=56]). The last 70 min before delivery were evaluated using "CTG-Online" and "CTG-Player". These results were correlated with foetal outcome.
Results:
In the time interval of 25 to 5 min before delivery, the FIGO parameter "deceleration" had a statistically significant correlation with poor foetal outcome (p<0.0199). Variability and acceleration showed no correlation during the evaluation period. Five minutes before delivery the baseline showed a weak statistically significant correlation with foetal outcome (p<0.0290).
Conclusions:
Norm values of the FIGO parameters baseline, acceleration and deceleration should be re-examined using large computer databases. Computerised analyses of the FIGO parameter for deceleration is promising, however, further studies are needed to increase its sensitivity and specificity.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...