A semi-automatic system for operation of electrical detection for a spark-source mass-spectrometer

R J Conzemius1, W A Rhinehart, H J Svec

  • 1Institute for Atomic Research and Department of Chemistry, Iowa State University, Ames, Iowa 50010, U.S.A.

Talanta
|October 1, 1972
PubMed
Summary

A new semi-automatic control system enhances spark-source mass spectrometry. This system enables close operator interaction with the instrument and computer for improved data acquisition and analysis.

Related Concept Videos

Mass Spectrometers01:16

Mass Spectrometers

This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...