Rapid coulometric method for the Kjeldahl determination of nitrogen

C A Boström1, A Cedergren, G Johansson

  • 1Department of Analytical Chemistry, University of Umeå, 901 87 Umeå, Sweden.

Talanta
|November 1, 1974
PubMed

Related Concept Videos

Coulometry: Overview01:00

Coulometry: Overview

Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
One-Compartment Open Model: Urinary Excretion Data and Determination of k01:11

One-Compartment Open Model: Urinary Excretion Data and Determination of k

The one-compartment open model leverages urinary excretion data to estimate renal clearance, which gauges the kidney's capacity to expel a drug. This method offers several benefits, including directly measuring drug elimination and assessing the kidney's contribution to overall drug clearance. However, this approach has limitations. It assumes sole renal excretion of the drug, which is not true for all drugs. Accurate urinary excretion and plasma drug concentration measurement can also be...
Precipitation Gravimetry01:03

Precipitation Gravimetry

Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Complexometric EDTA Titration Curves01:20

Complexometric EDTA Titration Curves

EDTA titration curves determine the free metal ion concentration. The titration curve represents the change in concentration of free metal ions (p function) as a function of the volume of EDTA added. This curve consists of three regions: before, at, and after equivalence points. Excess free metal ions are present before the equivalence point. Equal concentrations of metal ions and EDTA are present at the equivalence point. After the equivalence point, excess EDTA exists. This means slight...