Related Experiment Video
Updated: Jun 28, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Determination of halide ions by cathodic stripping analysis
1Department of Chemistry, The University, Southampton, U.K.
Cathodic stripping analysis accurately determines halide ions in water within a 2 x 10(-5)-10(-3)M range. This method is effective for single halides and usually works for mixtures, with interferences also addressed.
Area of Science:
- Analytical Chemistry
- Electrochemistry
Background:
- Halide ion determination is crucial in environmental and industrial monitoring.
- Existing methods may face limitations in sensitivity or selectivity for complex samples.
Purpose of the Study:
- To evaluate cathodic stripping analysis for quantifying halide ions in aqueous solutions.
- To establish the linear response range and assess the method's applicability to single and mixed halide samples.
Main Methods:
- Utilized cathodic stripping voltammetry for halide ion analysis.
- Investigated the analytical response across a specific concentration range (2 x 10(-5)-10(-3)M).
- Examined the impact of halide mixtures and potential interferences on the analysis.
Main Results:
- Demonstrated a linear relationship between signal response and halide concentration for single ions.
- Confirmed the method's capability for analyzing mixtures of halide ions with high reliability.
- Identified and considered various potential interfering species.
Conclusions:
- Cathodic stripping analysis provides a reliable and sensitive method for halide ion determination in aqueous media.
- The technique is suitable for both individual halide quantification and the analysis of complex halide mixtures.
- Further considerations for interferences enhance the method's practical applicability.
More Related Videos
12:43The Synthesis of [Sn10(Si(SiMe3)3)4]2- Using a Metastable Sn(I) Halide Solution Synthesized via a Co-condensation Technique
Published on: November 28, 2016
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Qualitative Analysis
For instance, group IV...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Transport Number
Electrodeposition
Electrodeposition can...
Precipitation Titration Curve: Analysis