Related Experiment Video
Updated: Jun 28, 2026

10:13
Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
Iodometric microdetermination of certain organic acids.
Talanta
|July 1, 1978
Summary
A new method accurately determines organic acids using potassium iodate and iodide. This rapid titration technique provides precise results within 3-5 minutes, ensuring reliable analytical outcomes.
Area of Science:
- Analytical Chemistry
- Organic Chemistry
Background:
- Accurate quantification of organic acids is crucial in various scientific disciplines.
- Existing methods for organic acid determination may be time-consuming or less precise.
Purpose of the Study:
- To develop and present a rapid and accurate analytical method for determining specific organic acids.
- To establish a reliable titration procedure for organic acid quantification.
Main Methods:
- The method involves treating an organic acid sample solution with solid potassium iodate and potassium iodide.
- Liberated iodine is subsequently titrated with sodium thiosulphate solution.
- The reaction and titration are completed within a 3-5 minute timeframe.
Main Results:
- The described method provides accurate determination of certain organic acids.
- The analytical results achieved an accuracy of within 0.3%.
- The procedure is rapid, requiring only a few minutes for completion.
Conclusions:
- This method offers a fast and precise approach for organic acid analysis.
- The high accuracy (0.3%) makes it suitable for quantitative applications.
- The use of readily available reagents (potassium iodate, potassium iodide, thiosulphate) enhances its practicality.
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Spectroscopy of Carboxylic Acid Derivatives
Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and unsymmetrical carbonyl vibration.
In the...
In the...
Microbial Growth Measurement: Direct Methods
Direct methods for measuring microbial populations in a culture are essential tools in microbiology, providing quantitative data for various applications. Among these, microscopic counts, plate counts, and serial dilution are widely used techniques, each with unique principles and applications.Microscopic CountsMicroscopic counting involves the use of a Petroff-Hausser chamber, a specialized microscope slide with a grid and defined depth. By observing a liquid culture under a microscope,...
Acid-Base Titration Curves
A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of 0.100...
For a titration carried out for 25.00 mL of 0.100...
Microbial Growth Measurement: Indirect Methods
Estimating microbial growth is essential for understanding population dynamics and environmental adaptations. Indirect methods provide valuable insights by measuring parameters such as turbidity, metabolic activity, and biomass, enabling efficient and reproducible assessments.During exponential growth, microbial cells scatter light proportionally to their biomass, a principle used in turbidity measurements. About one million cells per milliliter produce detectable scattering, which a...