Related Experiment Video
Updated: Jun 28, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Determination of total arsenic by use of a zinc-column arsine generator
1Department of Oceanography, The University, Southampton, England.
Abstract:
A method for the measurement of total arsenic in extracts of environmental materials is described. Arsenic is reduced to arsine with a zinc reductor column, the evolved arsine is decomposed in a heated carbon-tube furnace, and arsenic determined by measurement of its atomic-absorption at 193.7 nm. The detection limit is 0.002 mug/ml and the coefficient of variation is 1.4% at 0.01 mug/ml.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Precipitation and Co-precipitation
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Emission Spectroscopy: Instrumentation