Multiparametric curve fitting-VII Determination of the number of complex species by factor analysis of potentiometric

J Havel1, M Meloun

  • 1Department of Analytical Chemistry, Purkyne University, Kotlárská 2, 611 37 Brno, Czechoslovakia.

Talanta
|March 1, 1985
PubMed

Related Concept Videos

Complexometric EDTA Titration Curves01:20

Complexometric EDTA Titration Curves

EDTA titration curves determine the free metal ion concentration. The titration curve represents the change in concentration of free metal ions (p function) as a function of the volume of EDTA added. This curve consists of three regions: before, at, and after equivalence points. Excess free metal ions are present before the equivalence point. Equal concentrations of metal ions and EDTA are present at the equivalence point. After the equivalence point, excess EDTA exists. This means slight...
Mechanistic Models: Compartment Models in Individual and Population Analysis01:23

Mechanistic Models: Compartment Models in Individual and Population Analysis

Mechanistic models are utilized in individual analysis using single-source data, but imperfections arise due to data collection errors, preventing perfect prediction of observed data. The mathematical equation involves known values (Xi), observed concentrations (Ci), measurement errors (εi), model parameters (ϕj), and the related function (ƒi) for i number of values. Different least-squares metrics quantify differences between predicted and observed values. The ordinary least squares (OLS)...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of 0.100...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...
Potentiometric Titration: Overview01:31

Potentiometric Titration: Overview

Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...