Determination of nitric acid concentration by using europium ion fluorescence
J C Coria-Garcia1, T M Niemczyk
1Department of Chemistry, University of New Mexico, Albuquerque, NM 87131, USA.
Abstract:
A method is presented for the determination of 2-10M nitric acid based on the fact that the presence of high nitric acid concentration causes an enhancement of the intensity of some bands in the fluorescence spectra of rare earth ions in solution. The 616-nm band of Eu(3+) shows the most dramatic intensity enhancement with increasing nitric acid concentration. The present method, based on the measurement of the ratio of Eu(3+) fluorescent band intensities is shown to be independent of Eu(3+) concentration and relatively free of interference. This robust method allows the presence of an interferent to be determined from the experimental data.
Related Concept Videos
Photoluminescence: Applications
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...