Automatic kinetic determination of oxazepam by the continuous addition of reagent technique

M Carmona1, M Silva, D Perez-Bendito

  • 1Department of Analytical Chemistry, Faculty of Sciences, University of Córdoba, 14004 Córdoba, Spain.

Talanta
|September 1, 1992
PubMed

Related Concept Videos

Fast Reactions01:27

Fast Reactions

Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...
One-Compartment Open Model: Urinary Excretion Data and Determination of k01:11

One-Compartment Open Model: Urinary Excretion Data and Determination of k

The one-compartment open model leverages urinary excretion data to estimate renal clearance, which gauges the kidney's capacity to expel a drug. This method offers several benefits, including directly measuring drug elimination and assessing the kidney's contribution to overall drug clearance. However, this approach has limitations. It assumes sole renal excretion of the drug, which is not true for all drugs. Accurate urinary excretion and plasma drug concentration measurement can also be...