Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Determination of arsenic compounds in reference materials by HPLC-(UV)-HG-AFS
Z Slejkovec1, J T van Elteren, A R Byrne
1Interfaculty Reactor Institute, Delft University of Technology, Mekelweg 15, 2629 JB Delft, Netherlands; Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia.
Abstract:
Arsenic compounds were determined in six reference materials of biological origin. None of them has yet been certified for arsenic compounds but some are in the process of certification; for most of these reference materials indicative literature values are available. Eight commonly used arsenic standards were used for quantification using a recently developed hyphenated speciation system comprising high performance liquid chromatography (HPLC) and atomic fluorescence spectrometry (AFS), interfaced via a UV-photoreactor and a hydride generation (HG) unit. Absolute detection limits were ca. 0.2 and 0.4 ng As for separation on anion and cation exchange columns, respectively. Our results agree well with indicative literature values which were generated by different authors using various separation and detection methods. The HPLC-(UV)-HG-AFS system validated in this way is suitable for quantification of eight arsenic compounds. Moreover, the system is capable of separation of at least six more compounds in the mentioned reference materials, of which two could be attributed to arsenosugars (OH and phosphodiester form) but due to the lack of standards, quantification was not possible. For accurate and extensive speciation analysis the availability of certified reference materials and standards for arsenic compounds should be promoted.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Fluorescence Spectroscopy
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...