Gas chromatography/sniffing port analysis of aroma compounds released under mouth conditions
1Department of Food Science and Technology, Nutritional Sciences, University College Cork, Western Road, Cork, Ireland.
Abstract:
The release of aroma compounds from rehydrated French beans in an artificial mouth system and in the mouths of 12 assessors was studied by gas chromatography combined with flame ionisation detection and sniffing port detection. In an artificial mouth system, volatile compounds were isolated under mouth conditions, such as temperature, salivation, and mastication. No significant differences were determined between the aroma release from the beans in the artificial mouth and release in the mouths of assessors. However, both the real and artificial mouth systems differed significantly from a purge-and-trap and a dynamic headspace system in aroma release. In order to study aroma release over time, volatile compounds were isolated from rehydrated French beans for 1, 1.5, 3 and 12 min in the artificial mouth system and analysed by gas chromatography/sniffing port analysis. 2-Methylpropanal, 2-/3-methylbutanal, hexanal, 2-methyl-2-butenal, 1-octen-3-one, and dimethyl trisulphide possessed detectable odours when isolated from the French beans in the artificial mouth for all time periods. The odour active compounds 2-/3-methylbutanal and hexanal were shown to be released at a constant rate. Different sampling times resulted in identical selections of aroma compounds, while mutual proportions were retained.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...