Related Experiment Video
Updated: Jun 28, 2026

Accumulation and Analysis of Cuprous Ions in a Copper Sulfate Plating Solution
Published on: March 20, 2019
Minimization of lead and copper interferences on spectrophotometric determination of cadmium using electrolytic
J A Gomes Neto1, A P Oliveira, G P Freshi
1Departamento de Quimica Analitica, Instituto de Quimica, Univ. Estadual Paulista (UNESP), PO Box 355, CEP 14801-970 Araraquara, SP, Brazil.
Abstract:
A new strategy for minimization of Cu(2+) and Pb(2+) interferences on the spectrophotometric determination of Cd(2+) by the Malachite green (MG)-iodide reaction using electrolytic deposition of interfering species and solid phase extraction of Cd(2+) in flow system is proposed. The electrolytic cell comprises two coiled Pt electrodes concentrically assembled. When the sample solution is electrolyzed in a mixed solution containing 5% (v/v) HNO(3), 0.1% (v/v) H(2)SO(4) and 0.5 M NaCl, Cu(2+) is deposited as Cu on the cathode, Pb(2+) is deposited as PbO(2) on the anode while Cd(2+) is kept in solution. After electrolysis, the remaining solution passes through an AG1-X8 resin (chloride form) packed minicolumn in which Cd(2+) is extracted as CdCl(4)(2-). Electrolyte compositions, flow rates, timing, applied current, and electrolysis time was investigated. With 60 s electrolysis time, 0.25 A applied current, Pb(2+) and Cu(2+) levels up to 50 and 250 mg l(-1), respectively, can be tolerated without interference. For 90 s resin loading time, a linear relationship between absorbance and analyte concentration in the 5.00-50.0 mug Cd l(-1) range (r(2)=0.9996) is obtained. A throughput of 20 samples per h is achieved, corresponding to about 0.7 mg MG and 500 mg KI and 5 ml sample consumed per determination. The detection limit is 0.23 mug Cd l(-1). The accuracy was checked for cadmium determination in standard reference materials, vegetables and tap water. Results were in agreement with certified values of standard reference materials and with those obtained by graphite furnace atomic absorption spectrometry at 95% confidence level. The R.S.D. for plant digests and water containing 13.0 mug Cd l(-1) was 3.85% (n=12). The recoveries of analyte spikes added to the water and vegetable samples ranged from 94 to 104%.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
11:49A Continuous-flow Photocatalytic Reactor for the Precisely Controlled Deposition of Metallic Nanoparticles
Published on: April 10, 2019
Related Concept Videos
Electrodeposition
Electrodeposition can...
Controlled-Current Coulometry: Overview
Extraction: Advanced Methods
Precipitation and Co-precipitation
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...