Ion-Exchange Membranes for the Fabrication of Reverse Electrodialysis Device
Published on: July 20, 2021
Use of self-plasticizing EVA membrane for potentiometric anion detection
K Y Torres1, C A Garcia, J C Fernandes
1Instituto de Quimica - UNICAMP, P.O. 6154, 13083-970 Campinas, SP, Brazil.
Talanta
|October 31, 2008
Summary
New anion-selective electrodes were developed using Aliquat-336S and EVA membranes. These sensors are effective for determining anions, including salicylate and iodide, in pharmaceutical samples with high accuracy.
Area of Science:
- Electrochemistry
- Materials Science
- Analytical Chemistry
Background:
- Development of selective membranes is crucial for accurate ion determination.
- Anion-selective electrodes offer a pathway for sensitive and specific analyte quantification.
- Previous methods often rely on plasticizers, which can leach and affect sensor performance.
Purpose of the Study:
- To develop and characterize novel anion-selective electrode membranes.
- To evaluate the performance of these membranes for anion determination in steady-state and flow injection analysis (FIA) systems.
- To assess the applicability of the developed sensors for analyzing pharmaceutical samples.
Main Methods:
- Fabrication of five distinct membranes using tri-caprylyl-trimethyl-ammonium chloride (Aliquat-336S) and poly(ethylene-co-vinyl-acetate) (EVA) copolymer.
- Preparation of sensors by solubilizing EVA and Aliquat-336S in chloroform without plasticizers.
- Evaluation of membrane performance in steady-state conditions and in a flow injection analysis (FIA) system with a tubular electrode.
- Determination of salicylate and iodide concentrations in pharmaceutical samples.
Main Results:
- The developed ion-selective electrodes demonstrated utility for anion determination in the concentration range of 10(-5) to 10(-1) mol L(-1).
- In the FIA system, the electrode showed a Nernstian response for salicylate (2.5x10(-3) to 1.0x10(-1) mol L(-1)) and iodide (5.0x10(-4) to 1.0x10(-1) mol L(-1)).
- The sensors achieved a relative deviation of 1.6% when compared to a reference method for salicylate and iodide determination in pharmaceutical samples.
Conclusions:
- Plasticizer-free membranes based on Aliquat-336S and EVA are effective for anion-selective electrodes.
- The developed sensors exhibit good performance in both steady-state and FIA systems.
- The sensors are suitable for the accurate determination of salicylate and iodide in pharmaceutical formulations.
Related Concept Videos
Potentiometry: Membrane Electrodes
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Potentiometry: Types of Electrodes
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Potential Coulometry: Electrolytic Methods
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
The chosen potential ensures...
Potentiometry: Overview
Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as the...
Electrodes: Overview
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...