Inductively coupled plasma optical emission spectrometric determination of trace elements in sediments after
Marco Grotti1, Carmela Ianni, Roberto Frache
1Department of Chemistry and Industrial Chemistry, University of Genoa, via Dodecaneso 31, I-16146 Genoa, Italy.
Abstract:
The interfering effects due to the reagents and matrix elements associated with a four step sequential extraction procedure on ICPOES determination of trace elements were investigated in a systematic way. The emission lines were selected in order to include the most interesting elements for environmental studies (Zn, Pb, Ni, Cr, V and Cu) and the concentrations ranged according with the values occurring in the real samples. In order to distinguish between chemical and physical interfering effects, the Mg 280.270-Mg 285.213 line intensity ratio was measured, in each condition. Both pneumatic and ultrasonic nebulization were considered for comparison. It was found that both the elements which constitute the sample and the reagents which are added during the sample preparation steps significantly influence the emission intensity of all the analytes, depending on the analytical concentration and the nebulization system. Generally, the signal variations were higher with ultrasonic nebulization. Concerning the interference mechanism, it was found that the effect of the major elements (Na, K, Mg, Ca, Al and Fe) is essentially related to a change of the aerosol generation and transport processes. Differently, acetic acid, ammonium acetate and hydroxylamine hydrochloride significantly improved the plasma excitation conditions, depending on their concentration. A change of the sample introduction efficiency due to the presence of these reagents was also evident. On the contrary, the effect of hydrochloric and nitric acid emerged to be related only to the processes occurring in the sample introduction system.
More Related Videos
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
11:50Metal-silicate Partitioning at High Pressure and Temperature: Experimental Methods and a Protocol to Suppress Highly Siderophile Element Inclusions
Published on: June 13, 2015
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Interference