Related Experiment Video
Updated: Jun 28, 2026

12:30
Development and Validation of Chromium Getters for Solid Oxide Fuel Cell Power Systems
Published on: May 26, 2019
Chromium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil)
1Department of Chemistry, Faculty of Science, University of Razi, Kermanshah, Iran.
Talanta
|October 31, 2008
Summary
A new poly(vinyl chloride) membrane electrode selectively detects chromium(III) ions. This Cr(III)-selective sensor offers a wide linear dynamic range and high sensitivity, proving effective for analyzing food and alloy samples.
Area of Science:
- Analytical Chemistry
- Electrochemistry
- Materials Science
Background:
- Chromium(III) is an essential trace element but can be toxic at higher concentrations.
- Accurate determination of Cr(III) is crucial for environmental monitoring and food safety.
- Development of selective and sensitive electrodes is vital for efficient Cr(III) analysis.
Purpose of the Study:
- To develop a novel poly(vinyl chloride) membrane electrode for selective Cr(III) ion detection.
- To characterize the electrode's performance, including its dynamic range, sensitivity, and response time.
- To evaluate the electrode's applicability in real-world sample analysis, such as food materials and alloys.
Main Methods:
- Fabrication of a poly(vinyl chloride) membrane incorporating glyoxal bis(2-hydroxyanil) as the ionophore.
- Electrochemical characterization using potentiometric measurements to determine selectivity and performance parameters.
- Testing the electrode's response across various concentrations, pH levels, and in the presence of interfering ions.
- Application of the developed electrode for Cr(III) determination in complex matrices like food samples and metal alloys.
Main Results:
- The Cr(III)-selective electrode exhibited a linear dynamic range from 3.0x10⁻⁶ to 1.0x10⁻² mol L⁻¹.
- A Nernstian slope of 19.8±0.5 mV per decade and a detection limit of 6.3x10⁻⁷ mol L⁻¹ were achieved.
- The electrode demonstrated a fast response time (<20 s), operational stability for over 3 months, and good selectivity for Cr(III) over other metal ions within a pH range of 2.7–6.5.
Conclusions:
- The developed glyoxal bis(2-hydroxyanil)-based poly(vinyl chloride) membrane electrode is a highly selective and sensitive sensor for Cr(III) ions.
- The electrode's robust performance and successful application in food and alloy analysis highlight its practical utility.
- This sensor offers a reliable and efficient method for the determination of chromium(III) in various industrial and environmental samples.
Related Concept Videos
Electrodeposition
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
Ion-Exchange Chromatography
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Extraction: Advanced Methods
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is formed in...
Ion Exchange
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or basic...
Masking and Demasking Agents
EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Precipitation of Ions
Predicting Precipitation
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: