Related Experiment Video
Updated: Jun 28, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Rapid capillary zone electrophoresis method for the determination of metal cations in beverages
Silvia Suárez-Luque1, Inés Mato, José F Huidobro
1Facultad de Farmacia, Departamento de Química Analítica, Nutrición y Bromatología, Area de Nutrición y Bromatología, Universidad de Santiago, 15782 Santiago de Compostela (Galicia), Spain.
Abstract:
A rapid and reliable capillary zone electrophoresis method for the determination of inorganic cations was developed. The complete separation of K(+), Ba(2+), Ca(2+), Na(+), Mg(2+), Mn(2+), Ni(2+), Cd(2+), Li(+) and Cu(2+) can be achieved in 4min with a simple electrolyte composed by 10mM imidazole as the carrier buffer and background absorbance provider and acetic acid as the complexing agent (pH 3.60). Injection was performed hydrostatically by elevating the sample at 10cm for 30s. The running voltage was +25kV at room temperature. Indirect UV-absorption detection was achieved at 185nm. The detection limit was in the range between 0.06mg/l (Mg(2+)) and 0.57mg/l (K(+)) and the quantification limits ranged from 0.10mg/l (Ni(2+)) to 0.80mg/l (Cu(2+)). The calibration graphs were linear in the concentration range from the quantification limit till at least 1g/l in K(+), 10mg/l in Ba(2+), Ca(2+), Mg(2+), Mn(2+), Ni(2+) and Cd(2+), 40mg/l in Na(+) and 12mg/l in Li(+) and Cu(2+). The repeatability, intraday and interday analysis were =1.55% and =3.64% for migration time and =3.38% and =3.63% for peak area. The method developed has been applied to several beverage samples with only a simple dilution and filtration treatment of the sample. The proposed method is simple, fast, cheap and it is achieved with common products in either laboratory. For these reasons, it is a very useful method for routine analysis.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Extraction: Advanced Methods
Qualitative Analysis
For instance, group IV...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Ion-Exchange Chromatography

