Background:
SARS-CoV-2 variant tracking is key to the genomic surveillance of the COVID-19 pandemic. While next-generation sequencing (NGS) is commonly used for variant determination, it is expensive and time-consuming. Variant-specific PCR (vsPCR) is a faster, cheaper method that detects specific mutations that are considered variant-defining. These tests usually rely on specific amplification when a mutation is present or a specific melting temperature peak after amplification.
Case Presentation:
A discrepant result between vsPCR and NGS was found in seventeen SARS-CoV-2 samples from Galicia, Spain. A cluster of BA.1 Omicron SARS-CoV-2 variant showed a BA.2-like melting temperature pattern due to a point mutation (C21772T) downstream the deletion of the spike amino acids 69/70. As the 69/70 deletion is widely used for differentiation between BA.1 and BA.2 by vsPCR, C21772T can cause BA.1 samples to be misinterpreted as BA.2. Over a thousand BA.1 sequences in the EpiCoV database contain this mutation.
Conclusions:
To our knowledge, this is the first case of a point mutation causing a vsPCR algorithm to misclassify BA.1 samples as BA.2. This is an example of how mutations in the probe target area of vsPCR tests based on melting curve analysis can lead to variant misclassification. NGS confirmation of vsPCR results is relevant for the accuracy of the epidemiological surveillance. In order to overcome the possible impact of novel mutations, diagnostic tools must be constantly updated.