Related Experiment Video
Updated: Jan 20, 2026

Automatic Laser-based Geometry Capture for Finite Element Analysis of Weld Beads
Published on: July 25, 2025
Automatic coregistration of volumetric images based on implanted fiducial markers
Martin Koch1, Jonathan S Maltz, Serge J Belongie
1Oncology Care Systems Group, Siemens Medical Solutions USA, Inc., 4040 Nelson Avenue, Concord, California 94520, USA. martin.koch@informatik.stud.uni-erlangen.de
Abstract:
The accurate delivery of external beam radiation therapy is often facilitated through the implantation of radio-opaque fiducial markers (gold seeds). Before the delivery of each treatment fraction, seed positions can be determined via low dose volumetric imaging. By registering these seed locations with the corresponding locations in the previously acquired treatment planning computed tomographic (CT) scan, it is possible to adjust the patient position so that seed displacement is accommodated. The authors present an unsupervised automatic algorithm that identifies seeds in both planning and pretreatment images and subsequently determines a rigid geometric transformation between the two sets. The algorithm is applied to the imaging series of ten prostate cancer patients. Each test series is comprised of a single multislice planning CT and multiple megavoltage conebeam (MVCB) images. Each MVCB dataset is obtained immediately prior to a subsequent treatment session. Seed locations were determined to within 1 mm with an accuracy of 97 +/- 6.1% for datasets obtained by application of a mean imaging dose of 3.5 cGy per study. False positives occurred in three separate instances, but only when datasets were obtained at imaging doses too low to enable fiducial resolution by a human operator, or when the prostate gland had undergone large displacement or significant deformation. The registration procedure requires under nine seconds of computation time on a typical contemporary computer workstation.
Related Concept Videos
Automatic Processing and Automatic Social Behavior
07:58Automatic Laser-based Geometry Capture for Finite Element Analysis of Weld Beads
07:13Multimodal Cross-Device and Marker-Free Co-Registration of Preclinical Imaging Modalities
08:56Simultaneous Imaging and Flow-Cytometry-based Detection of Multiple Fluorescent Senescence Markers in Therapy-Induced Senescent Cancer Cells
08:06Robotic Cochlear Implantation for Direct Cochlear Access
08:39High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately

