Related Experiment Video
Updated: Jun 28, 2026

Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
Live/real time three-dimensional transthoracic echocardiographic assessment of pulmonary regurgitation
Koteswara R Pothineni1, Bryan J Wells, Ming Chon Hsiung
1Division of Cardiovascular Disease, University of Alabama at Birmingham, Birmingham, Alabama 35249, USA.
Abstract:
There is no gold standard for the measurement of pulmonary regurgitation (PR) severity. Two-dimensional (2D) transthoracic echocardiography is most commonly used to quantify PR severity using color Doppler criteria for aortic regurgitation. However, this method is limited by visualization of only one or two dimensions of the proximal PR jet or vena contracta (VC) precluding accurate assessment of its shape or size. This limitation would be expected to be obviated by three-dimensional (3D) transthoracic echocardiography, which could provide a more accurate quantitative assessment of PR severity. This study evaluated 82 adult patients with PR using 2D and 3D. PR VC area by 3D was obtained by planimetry by positioning the cropping plane exactly parallel to the VC, which was viewed en face by cropping of the 3D data set. Regurgitant volumes were calculated by 2D (assuming a circular VC) and by 3D as a product of the VC and velocity time integral obtained by color Doppler-guided conventional Doppler interrogation of the PR jet.The 3D VC area correlated with 2D jet width (JW)/right ventricular outflow tract (RVOT) width (r = 0.71) and 2D VC area (r = 0.79). 3D JW/RVOT width correlated with 2D JW/RVOT (r = 0.87). 3D regurgitant volumes also correlated with 2D regurgitant volumes (r = 0.76). The 3D VC values of <0.20, 0.20-0.45, 0.46-1.15, and >1.15 cm(2) and regurgitant volumes of <15 ml, 15-50 ml, 51-115 ml, and >115 ml were effective as cutoffs for grades 1, 2, 3, and 4 PR, respectively. In conclusion, quantification of 3D VC area and regurgitant volumes correlate reasonably well with the current 2D methods for measurement of PR. Since 3D visualizes PR VC in three dimensions, it would be expected to provide a more accurate and more quantitative assessment of PR severity as compared to 2D.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Aortic Regurgitation IV: Nursing Management
Aortic Regurgitation I: Introduction
Mitral Regurgitation III: Medical Management
