Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
3.0-T MR imaging of the abdomen: comparison with 1.5 T
Kevin J Chang1, Ihab R Kamel, Katarzyna J Macura
1Department of Diagnostic Imaging, Rhode Island Hospital and The Miriam Hospital, Warren Alpert Medical School of Brown University, Providence, RI 02903, USA. kchang@lifespan.org
Abstract:
Three-tesla magnetic resonance (MR) imaging offers substantially higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than 1.5-T MR imaging does, which can be used to improve image resolution and shorten imaging time. Because of these increases in SNR and CNR, as well as changes in T1 and T2 relaxation times, an increase in magnetic susceptibility, and an increase in chemical shift effect, many abdominal applications can benefit from 3.0-T imaging. Increased CNR obtained with a gadolinium-based contrast agent improves lesion conspicuity, requires less intravenous contrast material, and improves MR angiography by increasing spatial and temporal resolution. Increased SNR improves fluid conspicuity and resolution for applications such as MR cholangiopancreatography. Increased chemical shift effect also improves spectral resolution for MR spectroscopy. Several potential problems remain for abdominal imaging at 3.0 T. Limitations on energy deposition may require compromises in pulse sequence timing and flip angles. These compromises result in prolonged imaging time and altered image contrast. Magnetic susceptibility and chemical shift artifacts are worsened, but they may be counteracted by shortening echo time, performing parallel imaging, and increasing bandwidth. Radiofrequency field inhomogeneity is also a major concern in imaging larger fields of view and often leads to standing wave effects and large local variations in signal intensity. Many issues related to MR device compatibility and safety have yet to be addressed at 3.0 T. A 3.0-T MR imaging system has a higher initial cost and a higher cost of upkeep than a 1.5-T system does.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI