Related Experiment Video
Updated: Jun 28, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Preconcentration and separation of neutral steroid analytes using a combination of sweeping micellar electrokinetic
1Department of Applied Chemistry, National University of Kaohsiung, No. 700, Kaohsiung University Road, Nan Tzu District, Kaohsiung 811, Taiwan. fkliu@nuk.edu.tw
Abstract:
This paper describes the preconcentration of three neutral steroids (testosterone, progesterone, and testosterone propionate) through a combination of off-line preconcentration using a gold nanoparticle (Au NP)-coated silica gel solid phase extraction (SPE) sorbent prior to on-line preconcentration using sweeping micellar electrokinetic chromatography (MEKC). In the initial phase of this study, the sweeping-MEKC parameters for the capillary electrophoresis (CE) separation of the steroid analytes were optimized. The sweeping-MEKC effect was greatest when the sample matrix contained ca. 18% acetonitrile and 100mM sodium dihydrogen phosphate (pH 7.0). Next, under the optimized sweeping-MEKC operating conditions, a commercial C(18)-bonded silica gel and a Au NP-coated silica gel were tested for their use as SPE sorbents for the SPE-sweeping-MEKC preconcentration of steroid-spiked urine samples. Of these two sorbents, the Au NP-coated SPE sorbent displayed a superior clean-up efficiency toward the sample matrix. Size exclusion chromatography (SEC) was used to characterize the interactions between urinary proteins and the Au NPs. The results indicated that the removal of the interfering signals from the urinary proteins was probably due to their interactions with residual Au metal surfaces of the Au NP-coated SPE sorbent. When combining Au NP-coated silica gel SPE with sweeping-MEKC for the CE analysis of steroid-spiked urine samples, the limits of detection (at a signal-to-noise ratio of N=3) for testosterone, progesterone, and testosterone propionate were ca. 1.59, 1.20, and 1.15mug/L, respectively; in addition, the detection sensitivities (based on peak heights) of these steroids improved by ca. 700-, 1090-, and 1100-fold, respectively, relative to those of the analytes that had not been subjected to preconcentration.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Ion-Exchange Chromatography
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...