Related Experiment Video
Updated: Jun 27, 2026

ELIME (Enzyme Linked Immuno Magnetic Electrochemical) Method for Mycotoxin Detection
Published on: October 23, 2009
Label-free impedimetric immunosensor for sensitive detection of ochratoxin A
Abd-Elgawad Radi1, Xavier Muñoz-Berbel, Vasilica Lates
1Department of Chemistry, Faculty of Science, Mansoura University, 34517 Dumyat, Egypt.
Abstract:
A novel label-free electrochemical impedimetric immunosensor for sensitive detection of ochratoxin A (OTA) was reported. A two-step reaction protocol was elaborated to modify the gold electrode. The electrode was first derivatized by electrochemical reduction of in situ generated 4-carboxyphenyl diazonium salt (4-CPDS) in acidic aqueous solution yielded stable 4-carboxyphenyl (4-CP) monolayer. The ochratoxin A antibody was then immobilized making use of the carbodiimide chemistry. The steps of the immunosensor elaboration and the immunochemical reaction between ochratoxin A and the surface-bound antibody were interrogated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The impedance change, due to the specific immuno-interaction at the immunosensor surface was utilized to detect ochratoxin A. The increase in electron-transfer resistance (DeltaR(et)) values was linearly proportional to the concentration of OTA in the range of 1-20ngmL(-1), with a detection limit of 0.5ngmL(-1).
