Detection of myocardial ischaemia by epicardial accelerometers in the pig
P S Halvorsen1, L A Fleischer, A Espinoza
1The Interventional Centre, Rikshospitalet University Hospital, N-0027 Oslo, Norway. per.steinar.halvorsen@rikshospitalet.no
Background:
We describe a novel technique for continuous real-time assessment of myocardial ischaemia using a three-axis accelerometer.
Methods:
In 14 anaesthetized open-chest pigs, two accelerometers were sutured on the left ventricle (LV) surface in the perfusion areas of the left anterior descending (LAD) and circumflex (CX) arteries. Acceleration was measured in the longitudinal, circumferential, and radial directions, and the corresponding epicardial velocities were calculated. Regional LV dysfunction was induced by LAD occlusion for 60 s. Global LV function was altered by nitroprusside, epinephrine, esmolol, and fluid loading. Epicardial velocities were compared with strain by echocardiography during LAD occlusion and with aortic flow and LV dP/dt(max) during interventions on global LV function.
Results:
LAD occlusion induced ischaemia, shown by lengthening in systolic strain in the LV apical anterior region (P<0.01) and concurrent changes in LAD accelerometer circumferential velocities during systole (P<0.01) and during the isovolumic relaxation phase (P<0.01). The changes in accelerometer circumferential velocities during LAD occlusion were greater compared with the changes during the interventions on global function (P<0.01). For the LAD accelerometer circumferential velocities, sensitivity was 94-100% and specificity was 92-94% in detecting ischaemia.
Conclusions:
Myocardial ischaemia can be detected with epicardial three-axis accelerometers. The accelerometer had the ability to distinguish ischaemia from interventions altering global myocardial function. This novel technique may be used for continuous real-time monitoring of myocardial ischaemia during and after cardiac surgery.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...