Stroke volume averaging for individualized goal-directed fluid therapy with oesophageal Doppler
C C Jørgensen1, M Bundgaard-Nielsen, L T Skovgaard
1Section of Surgical Pathophysiology, Rigshospitalet, Copenhagen, Denmark.
Background:
An individualized fluid optimization strategy, based on maximization of cardiac stroke volume (SV) with colloid boluses (goal-directed therapy), improves outcome after surgery. Oesophageal Doppler (OD) is used for SV maximization in most randomized studies, but evidence-based guidelines for the SV maximization procedure are lacking and variation in SV may influence the indication for fluid administration. We measured beat-to-beat OD SV before and after fluid optimization in order to estimate the number of heartbeats for which SV needs to be averaged to provide an acceptable accuracy for goal-directed therapy with this technology.
Methods:
Twenty patients scheduled for surgery were anaesthetized, followed by OD SV assessment. Thirty seconds of beat-to-beat data were recorded before and after volume optimization performed by successive boluses of 200 ml colloid until SV did not increase >or=10%. SV variability was assessed before and after the volume optimization when SV was measured beat to beat and when it was averaged over 2-10 heartbeats.
Results:
Nineteen (95%) and 17 (85%) patients demonstrated an SV variability >or=10% before and after volume optimization, respectively, when SV was measured beat to beat. However, when SV was averaged over 10 heartbeats, only two (10%) and one (5%) of the patients demonstrated an SV variability >or=10% before and after optimization, respectively (P<0.0001).
Conclusion:
OD SV variability is significantly reduced and reaches an acceptable level when SV is averaged over 10 heartbeats. The use of a shorter averaging period for SV may lead to incorrect volume administration in goal-directed fluid management.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Urodynamic Studies: Uroflowmetry
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.