Background:
Airway management, the first step in resuscitation, may entail special difficulties in mass casualty situations, even in experienced hands. Of the available airway devices, the cuffed oropharyngeal airway (COPA) appears the easiest one to insert, allowing a hands-free anaesthesiologist. A study was undertaken to evaluate the success of airway control with COPA when anaesthetists wore either surgical attire or antichemical protective gear.
Methods:
Twelve anaesthetists with 2-5 years of residency inserted COPA in 24 anaesthetised patients in a random crossover prospective manner. The duration of airway management was measured from the time the device was grasped to obtaining a normal capnography recording; time to proper fixation was also recorded.
Results:
Time to COPA placement was significantly shorter when the anaesthetists wore surgical attire than when they wore protective gear (28 (10) s vs 56 (34) s, p<0.05). Time to proper fixation of the COPA to patients' faces also differed significantly (19 (14) s with surgical attire vs 34 (16) s with protective gear, p<0.05). First-time COPA insertion failure was statistically similar in both groups. There was no hypoxaemia.
Conclusions:
Antichemical protective gear slowed proper placement of COPA and its fixation compared with surgical attire. COPA may be a temporarily useful device in non-conventional settings, but functional reassessment is required when injured patients reach medical facilities.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques