Increasing uptake time in FDG-PET: standardized uptake values in normal tissues at 1 versus 3 h
Bennett B Chin1, Edward D Green, Timothy G Turkington
1Department of Radiology, Division of Nuclear Medicine, Duke University Medical Center, Durham, NC, USA, chin0004@mc.duke.edu.
Objective:
Positron emission tomography (PET) imaging at more than 1 h after 2-deoxy-2-[(18)F]fluoro-D: -glucose (FDG) administration may result in less blood pool activity and possibly decreased normal FDG uptake in tissues such as liver. Lower normal background activity could be an important component of improved image contrast on delayed imaging. Increasing FDG uptake in normal organs, however, may mitigate the beneficial effects of blood pool clearance. The purpose of this study is to determine the normal tissue and blood pool FDG uptake at 1 and 3 h after injection.
Subjects And Methods:
Ninety-nine patients with known or suspected malignancy referred for FDG-PET-computed tomography (CT) were retrospectively evaluated. PET imaging was performed at either 1 h (60 +/- 15 min; n = 50) or at 3 h (180 +/- 15 min; n = 49) after FDG administration. Normal tissue FDG uptake without involvement by malignancy or influenced by artifact (misregistration, "brown fat," focal muscle uptake, focal atherosclerotic disease) was confirmed by inspection of both the PET and CT scans. Aortic blood pool, adipose tissue, bone marrow, cerebellum, liver, lungs, muscle, and spleen were quantitatively evaluated by CT-guided region of interest analysis in three contiguous slices. Mean standardized uptake values (SUVs) were analyzed using one-way analysis of variance.
Results:
Mean SUVs on the 3- versus 1-h images were significantly lower for aortic blood pool 13% (p < 0.0001) and adipose tissue 20% (p < 0.008). FDG uptake showed significant increases at 3 h compared to 1-h imaging in the cerebellum 40% (p < 0.0001), bone marrow 25% (p = 0.003), muscle 21% (p = 0.0004), and spleen 13% (p = 0.01). The liver and lung showed no significant differences (1%, p = 0.85; -2%, p = 0.62, respectively).
Conclusions:
On FDG imaging at 3 h compared to 1 h, significant changes were apparent, but the magnitude of changes was modest overall. Three-hour delayed imaging demonstrated significantly lower aortic blood pool and adipose tissue activity and significantly higher cerebellum, muscle, spleen, and bone marrow activity. Hepatic and lung activities were not significantly different. These results suggest that previously reported improvements in tumor image contrast with delayed imaging may be primarily due to cumulative FDG uptake within the tumor rather than reduction in normal background activity.
More Related Videos
09:58Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...